Be a solid backing with professional services. Provide 7x24-hour engineers and customize personalized services according to your needs.
Perfect solution, excellent service system
We pay attention to the latest information on the Internet and communicate the key points to our customers.
We are a company specializing in the development and production of network structured cabling products, dedicated to meeting and exceeding the needs of our customers, providing complete end-to-end solutions for the entire cabling system.
contact number:010-82405888
Category 6 STP Six Categories Four Pairs of shielded Cable
Implementation Standard ISO/IEC11801 & TIA- 568-C.2 & UL Subject 444 & YD/T1019
Application scope For network cabling system.Including10/100/1000Base -T,ATM & Token Ring
The shielded cable has a frequency of 250 MHz and meets the requirements of international standards for Six types of performance.
Structure
Conductor |
23AWG Annealed Soft Copper Wire |
Insulation |
polyethylene |
Line Pair Colors |
White/Blue-/Blue, White/Orange-Orange, White/Green-Green, White/Brown-Brown |
Shielding mode |
Aluminum plastic composite belt |
Outer sheath |
Nominal diameter7.0+/- 0.5 mm |
Additional description |
Normally no tear rope or according to customer requirements Centralization improves performance |
Print black font on sheath, print information according to customer's requirement |
Mechanical properties
100 Newton |
|
Minimum bending radius |
8 times cable diameter |
Nominal weight |
55KG/KM |
Working temperature |
-15Deg C ~ +60 Deg C |
Installation temperature |
+0 Deg C ~ +50 Deg C |
Combustibility of PVC |
PVC:VW1,CMX, CM, CMG, CMR, IEC60332.1 LSZH:IEC60332.1, IEC60332.3 Choose according to the type of sheath |
Supply cable length
Product length |
Standard length 305 meters; According to customer requirements |
Product characteristics
PROUVON Six types of shielded cables meet and exceed TIA/EIA-568-B.2 and ISO/IEC11801 international wiring standards |
Performance Requirements of Electromagnetic Compatibility (EMC) for High Environmental Requirements |
The center is a plastic cross skeleton, which can effectively prevent the performance degradation caused by the change of the twisting moment between the pairs of wires. |
Single-layer aluminum foil structure can effectively shield external electromagnetic interference. |
Over the 7dB performance margin of the six standards. |
Enhance bandwidth and network performance, support bandwidth 550MHz. |
Gigabit Ethernet applications are fully supported. |
According to UL's CMR flame retardant grade, low smoke halogen-free products meet relevant flame retardant (IEC332/3), low smoke (IEC1034), halogen-free (IEC754) standards. |
Products offer 25-year warranty |
Electrical properties
Transmission frequency (MHz) |
1 |
4 |
10 |
16 |
20 |
31.25 |
62.5 |
100 |
200 |
250 |
Proximal crosstalk (decibel) |
74..3 |
65.3 |
59.3 |
56.2 |
54.8 |
51.9 |
47.4 |
44.3 |
39.8 |
38.3 |
Characteristic impedance (ohm) |
100+/- 15 |
|||||||||
Attenuation (decibel/100m) |
74..3 |
65.3 |
59.3 |
56.2 |
54.8 |
51.9 |
47.4 |
44.3 |
39.8 |
38.3 |
Echo loss (decibel) |
74..3 |
65.3 |
59.3 |
56.2 |
54.8 |
51.9 |
47.4 |
44.3 |
39.8 |
38.3 |
Proximal crosstalk power and (decibel) |
74..3 |
65.3 |
59.3 |
56.2 |
54.8 |
51.9 |
47.4 |
44.3 |
39.8 |
38.3 |
Isolevel distal crosstalk (decibel) |
74..3 |
65.3 |
59.3 |
56.2 |
54.8 |
51.9 |
47.4 |
44.3 |
39.8 |
38.3 |
Isolevel distal crosstalk power and (decibel) |
74..3 |
65.3 |
59.3 |
56.2 |
54.8 |
51.9 |
47.4 |
44.3 |
39.8 |
38.3 |
Transmission phase delay ns/100m |
74..3 |
65.3 |
59.3 |
56.2 |
54.8 |
51.9 |
47.4 |
44.3 |
39.8 |
38.3 |
Transmission delay ns/100m |
≤45 |
Ordering Information
Product Description |
Product Number |
Indoor Four pairs of shielded cables of Class 6 cable, grey, 1000FT |
SC6004 |
Indoor Four pairs of shielded low smoke halogen-free cable, 1000FT |
SC6004-LH |
|
|
|
|
|