Be a solid backing with professional services. Provide 7x24-hour engineers and customize personalized services according to your needs.
Perfect solution, excellent service system
We pay attention to the latest information on the Internet and communicate the key points to our customers.
We are a company specializing in the development and production of network structured cabling products, dedicated to meeting and exceeding the needs of our customers, providing complete end-to-end solutions for the entire cabling system.
contact number:010-82405888
Category 6A UTP Ultra-Six Categories Four Pairs of Unshielded Cable
Implementation Standard ISO/IEC11801 & TIA- 568-C.2 & UL Subject 444 & YD/T1019
Application scope For network cabling system.Including10/100/1000Base -T,ATM 10G & Token Ring
The unshielded cable has a frequency of 500 MHz and meets the requirements of international standards for Ultra-Six Categories of performance.
Structure
Conductor |
23AWG Annealed Soft Copper Wire |
Insulation |
High density polyethylene |
Line Pair Colors |
White/Blue-Blue, White/Orange-Orange, White/Green-Green, White/Brown-Brown |
Shielding mode |
no |
Outer sheath |
PVC or LSZH according to customer's specific requirements |
Sheath outer diameter |
Nominal diameter 8.4 +/-0.5 mm |
Additional description |
Normally no tear rope or according to customer requirements |
Print black font on sheath, print information according to customer's requirement |
Mechanical properties
100 Newton |
|
Minimum bending radius |
8 times cable diameter |
Nominal weight |
55KG/KM |
Working temperature |
-15Deg C ~ +60 Deg C |
Installation temperature |
+0 Deg C ~ +50 Deg C |
Combustibility of PVC |
PVC:VW1,CMX, CM, CMG, CMR, IEC60332.1 LSZH:IEC60332.1, IEC60332.3according to customer needs. |
Supply cable length
Product length |
Standard length 305 meters; According to customer requirements |
Product characteristics
PROUVON 6A cable stabilizes a new performance evaluation index. When used as horizontal wiring in the system, significant margin space can be provided. |
Provide 500 MHZ bandwidth network applications for users with our high performance 6A connection hardware |
Bandwidth Test Requirements Through TIA/EIA568-B500MHZ |
Supports all applications for six or lower level wiring systems |
The near-end crosstalk loss (NEXT) is reduced and the impedance stability is maintained. |
Precise pitch matching and balancing design of different pairs of twisted lines reduces the near-end crosstalk loss (NEXT) |
Maximum bandwidth and SNR margin for mission-critical transmission |
Outdoor sheath has the characteristics of waterproof and rodent bite-proof. |
Products offer 25-year warranty |
Products offer 25-year warranty |
Electrical properties
Transmission frequency (MHz) |
1 |
4 |
10 |
16 |
20 |
31.25 |
62.5 |
100 |
200 |
250 |
500 |
|||||
Proximal crosstalk (decibel) |
74..3 |
65.3 |
59.3 |
56.2 |
54.8 |
51.9 |
47.4 |
44.3 |
39.8 |
38.3 |
33.8 |
|||||
Characteristic impedance (ohm) |
100+/- 15 |
100+/- 22 |
100+/- 25 |
|||||||||||||
Attenuation (decibel/100m) |
2.1 |
3.8 |
5.9 |
7.5 |
8.4 |
10.5 |
15.0 |
19.1 |
27.6 |
31.1 |
45.3 |
|||||
Echo loss (decibel) |
20 |
23 |
25 |
25 |
25 |
23.6 |
21.5 |
20.1 |
18 |
17.3 |
15.2 |
|||||
Proximal crosstalk power and (decibel) |
72.3 |
63.3 |
57.3 |
54.2 |
52.8 |
49.9 |
45.4 |
42.3 |
37.8 |
36.3 |
31.8 |
|||||
Isolevel distal crosstalk (decibel) |
67.8 |
55.8 |
47.8 |
43.7 |
41.8 |
37.9 |
31.9 |
27.8 |
21.8 |
19.8 |
13.8 |
|||||
Isolevel distal crosstalk power and (decibel) |
64.8 |
52.8 |
44.8 |
40.7 |
38.8 |
34.9 |
28.9 |
24.8 |
18.8 |
16.8 |
10.8 |
|||||
Outside-of-line and proximal crosstalk dB |
92.5 |
83.5 |
77.5 |
74.4 |
73.0 |
70.1 |
65.6 |
62.5 |
58.0 |
56.5 |
52.0 |
|||||
Distal Crosstalk Outside Integrated Line (dB) |
78.2 |
66.2 |
58.2 |
54.1 |
52.2 |
48.3 |
42.3 |
38.2 |
32.2 |
30.2 |
24.2 |
|||||
Transmission phase delay ns/100m |
552 |
547 |
545 |
543 |
542 |
541 |
540 |
539 |
538 |
537 |
535 |
|||||
Transmission delay ns/100m |
≤45 |
Ordering Information
Product Description |
Product Number |
Indoor ultra-six Categories and four pairs of unshielded cables , grey, 1000FT |
UC6A04 |
Indoor ultra-six Categories and four pairs of unshielded low smoke halogen-free cables, 1000FT |
UC6A04-LH |
|
|
|
|
|